From fd38f961730ce7c9804774900c14b58f2613ea12 Mon Sep 17 00:00:00 2001 From: wimh Date: Sat, 19 Sep 2020 20:17:11 +0200 Subject: [PATCH] detect /sys/class/power_supply/cw2015-battery, do not use charge_counter --- internal/p10k.zsh | 6 +++--- 1 file changed, 3 insertions(+), 3 deletions(-) diff --git a/internal/p10k.zsh b/internal/p10k.zsh index aeb997c9..a00ade71 100644 --- a/internal/p10k.zsh +++ b/internal/p10k.zsh @@ -1270,7 +1270,7 @@ _p9k_prompt_battery_init() { return fi if [[ $_p9k_os != (Linux|Android) || - -z /sys/class/power_supply/(CMB*|BAT*|battery)/(energy_full|charge_full|charge_counter)(#qN) ]]; then + -z /sys/class/power_supply/(CMB*|BAT*|*battery)/(energy_full|charge_full)(#qN) ]]; then typeset -g "_p9k__segment_cond_${_p9k__prompt_side}[_p9k__segment_index]"='${:-}' fi } @@ -1328,7 +1328,7 @@ _p9k_prompt_battery_set_args() { Linux|Android) # See https://sourceforge.net/projects/acpiclient. - local -a bats=( /sys/class/power_supply/(CMB*|BAT*|battery)/(FN) ) + local -a bats=( /sys/class/power_supply/(CMB*|BAT*|*battery)/(FN) ) (( $#bats )) || return local -i energy_now energy_full power_now @@ -1336,7 +1336,7 @@ _p9k_prompt_battery_set_args() { local dir for dir in $bats; do local -i pow=0 full=0 - if _p9k_read_file $dir/(energy_full|charge_full|charge_counter)(N); then + if _p9k_read_file $dir/(energy_full|charge_full)(N); then (( energy_full += ${full::=_p9k__ret} )) fi if _p9k_read_file $dir/(power|current)_now(N) && (( $#_p9k__ret < 9 )); then