@ -1407,7 +1407,7 @@ _p9k_prompt_battery_set_args() {
(( $#bats )) || return
local -i energy_now energy_full power_now
local -i is_full=1 is_calculating is_charching
local -i is_full=1 is_calculating is_charching only_unknown_found=1
local dir
for dir in $bats; do
local -i pow=0 full=0
@ -1423,6 +1423,8 @@ _p9k_prompt_battery_set_args() {
(( energy_now += _p9k__ret ))
fi
_p9k_read_file $dir/status(N) && local bat_status=$_p9k__ret || continue
[[ $bat_status == Unknown ]] && continue
only_unknown_found=0
[[ $bat_status != Full ]] && is_full=0
[[ $bat_status == Charging ]] && is_charching=1
[[ $bat_status == (Charging|Discharging) && $pow == 0 ]] && is_calculating=1
@ -1433,7 +1435,7 @@ _p9k_prompt_battery_set_args() {
bat_percent=$(( 100. * energy_now / energy_full + 0.5 ))
(( bat_percent > 100 )) && bat_percent=100
if (( is_full || (bat_percent == 100 && is_charching) )); then
if (( is_full || (bat_percent == 100 && (is_charching || only_unknown_found) ) )); then
state=CHARGED
else
if (( is_charching )); then

Loading…
Cancel